Downloads for digitalYEWFLO(DY)
Features: digitalYEWFLO Vortex Flowmeter
- | New functions with Spectral Signal Processing (SSP) technology |
SSP analyses the fluid conditions inside the digitalYEWFLO vortex flowmeter and uses the data to automatically select the optimum adjustment for the application, providing features never seen before in a vortex flowmeter. SSP accurately senses vortices in the low flow range, providing outstanding flow stability. | |
- | Advanced self-diagnostics |
Application conditions such as high pipeline vibration and abnormal flow are predicted and indicated. | |
- | High accuracy |
±0.75% of reading (liquid) ±1.0% of reading (gas, steam) | |
- | Wide process temperature range |
High temperature version up to 450 deg C Cryogenic version minimum -196 deg C | |
- | Simple parameter settings |
Frequently-used selections grouped together in a quick-access format decrease commissioning time | |
- | Clear, concise indicator |
Convenient display of the simultaneous and total flow rates together with the process diagnosis | |
- | Dual output for analog/pulse |
Simultaneous output for flow rate and pulse | |
- | Alarm output |
An alarm signal is output when an alarm occurs. | |
- | BRAIN/HART communication and key switches for human-machine interface |
- | NACE compliant |
- | NAMUR 43 compliant |
- | Remote cable length up to 30m |
Specifications: digitalYEWFLO Vortex Flowmeters
Standard | Multi-Variable | Reduced Bore | |
Model & code | DY Vortex Flowmeter | Optional code:/MV | Option code:/R1,/R2 |
Fluid to be measured | Liquid, gas, steam (avoid multiphase flow and sticky fluids) | ||
Nominal size | 15mm ∼ 300mm (400mm:special) | 25mm ∼ 200mm | 25mm ∼ 200mm |
Accuracy | Liquid: ±1.0% of reading (20000≤Re≤1000) Liquid: ±0.75% of reading (D×1000≤Re) | Liquid: ±1.0% of reading (20000≤Re≤1000) | |
Gas, steam: ±1.0% of reading (flow velocity less than 35m/s) Gas, steam: ±1.5% of reading (flow velocity 35m/s ∼ 80m/s) | |||
Output signal | Simultaneous output(both analog and transistor contact output available) | ||
Process temperature range | -29 deg C - 260 deg C (standard) | -29 deg C - 260 deg C (standard) | -29 deg C - 260 deg C (standard) |
-196 deg C∼100 deg C (option: cryogenic version) | N/A | N/A | |
-29 deg C∼450 deg C (option: high process temperature version) | N/A | -29 deg C∼450 deg C (option: high process temperature version) | |
Process pressure limit | -0.1MPa (-1kg/cm2) to flange rating | ||
Ambient temperature | -29 to 85 deg C (Integral type / No indicator) -29 to 80 deg C (Integral type / with indicator) -29 to 85 deg C (Remote type detector) -40 to 85 deg C (Remote type converter / No indicator) -30 to 80 deg C (Remote type converter / with indicator) | ||
Ambient humidity | 5~100%RH( Non-condensing) | ||
Mounting | Integral type and Remote type detector: Flange mounting or wafer mounting Remote type converter: 2 inch pipe mounting JIS10/20/40, ANSI150/300/600/900, JPI150/300/600,DIN PN10/16/25/40 | ||
Electrical connection | JIS G1/2 female, ANSI 1/2NPT female, ISO M20×1.5 female | ||
Electrical classification | JIS flameproof, FM explosion proof/intrinsically safe ATEX (CENELEC flameproof/intrinsically safe/IEC type n) CSA explosion proof/intrinsically safe : Dual Seal SAA flame proof/intrinsically safe | ||
Material | Body: SCS14A cast stainless steel (equivalent to SUS316,CF8M) Shedder bar: duplex stainless steel (option:anti-corrosion version) Gasket: SUS316 stainless steel with polytetrafluoroethylene (Teflon) coating Converter housing and case cover: aluminum alloy or ASTM CF8M (equiv. JIS SCS14A) (Option: /E1) | ||
Applicable Standard | *EMC Conformity Standards: EN61326-1 Class A, Table 2 (For use in industrial locations), EN61326-2-3 EN55011 Class A Group 1 *Pressure Equipment Directive: Notified Body Identification Number 0038 Module H |