| EJX120A Differential Pressure Transmitter | |
E Capsule | ||
Range | -1 to 1 kPa | |
(-4 to 4 inH2O) | ||
Span | 0.025 to 1 kPa | |
(0.1 to 4 inH2O) | ||
Accuracy | ±0.09% | |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | |
Certificates | FM, CENELEC ATEX, CSA, IECEx | |
Output | 4 to 20 mA DC or FOUNDATION™ fieldbus, 2-wire system with digital communication | |
Supply voltage | BRAIN and HART:10.5 to 42 V DC | |
(10.5 to 30 V DC for Intrinsically safe type) | ||
Fieldbus:9 to 32 V DC | ||
(9 to 24 V DC for Entity and 9 to 17.5 V DC for FISCO) | ||
Ambient temperature | -25 to 80 deg C (-13 to 176 deg F) (general use type) | |
Process temperature | -25 to 80 deg C (-13 to 176 deg F) (general use type) | |
Maximum working pressure | 50 kPa | |
(7.25 psi) | ||
Mounting | 2-inch pipe mounting | |
Wetted parts material | Capsule | 316L SST(Diaphragm material is Hastelloy C-276) |
Cover flange | ASTM CF-8M | |
Housing | Cast aluminum alloy or ASTM CF-8M stainless steel (optional) |
To start your quick quote, please fill out the below form and an China Industry Automation representative will contact you within an hour.